Epicare Pump Chamber Change; Light Age is the only manufacturer in Turkey that owns the Pump Chamber Patent, which can produce a new one of the laser head of the Epicare device called "Pump Chamber". Epicare Reflector; The reflective surface can be damaged and cracked due to thermal expansions or broken due to excessive energy and stresses on the glass. Cooling water can be trapped between the coating and reflective surfaces, causing the area to reach high temperatures and corrode the coating, darkening it and reducing the reflectivity of the area. Such damaged reflective surfaces are replaced with new reflective plates to ensure that they fulfill all their functions.

Epicare Flash Lamp;Since Epicare Flash lamps operate by jumping electric current from the cathode end to the anode end under high voltage each time to produce each laser pulse, the cathode material wears out. In addition, the cooling water is ionized with each laser pulse. A deionized filter holds the ions in the cooling water. However, since the outdated DI filter cannot hold the ions, electric jumping may occur to the ions passing around the lamps and thus surface damage occurs on the flash lamps. Metal dust forms inside the lamp and power loss occurs. In this case, the lamps need to be replaced.

Fiber Optic Cable;Repair and renewal of fiber optic cables of Light Age Epicare devices. Epicare Fiber Optic Cable; The laser light produced by the pump chamber is focused and enters the fiber cable and the laser light is applied to the patient's skin with the lens at the end of the handpiece by moving through the fragile glassy structure inside. Since this optical structure looks like a cable, it is often exposed to use like an electric cable. For this reason, the glass inside can break. Unwanted impurities can form at both ends of the fiber and the laser can burn and stick these impurities to the surface. For these reasons, it may need to be replaced or repaired.

Optics (Lens and Mirror) Change;Replacement of all mirrors and lenses on Light Age Epicare devices. Epicare Optical Lenses and Mirrors; Outputcoupler OC, High Reflector HR, 45 degree reflector and Focusing lenses are used on the optical table for the pump cahmber to generate laser light and focus it on the fiber cable. Since these lenses are exposed to laser energy for a long time, damage occurs over time and the coatings may burn due to this. There should be no dust in the environment. Damaged lenses can cause a decrease in laser energy and damage the optical system with scattering. Such lenses and mirrors must be replaced with new ones.

Electronic Card Repair;Light Age Epicare LPX, DUO devices motherboard, simmer unit, timing card, power supplies, fuse cards and PFN capacitor renewal and repair. Epicare Electronic Repair; Laser devices are intensive devices. Patient appointments are made one after the other. Electronic components may be damaged by overheating in devices used at high speed and devices that are not rested between appointments and whose environment is not sufficiently cooled with air conditioning.

HVPS Power Supply RepairHigh voltage power supply repair of Light Age Epicare LPX, DUO devices (High Voltage Power Supply). Epicare Power Supply Repair; In Epicare laser devices, the devices are usually operated with a water cycle of approximately 50 °C to provide optical power. When the power supplies are used at high speed and the environment is not sufficiently cooled by air conditioning, electronic components can be damaged by overheating. In laser devices that are used intensively, electronic components may be stressed and malfunction. In this case, the necessary parts should be replaced with new ones, power tested and restored to working condition.

PFN Repair;Light Age Epicare LPX, DUO devices (Pulse Forming Network, PFN) laser pulse determination unit renewal and repair. Epicare PFN Repair; PFN (Pulse Forming Netwrok) devices are used in Epicare Laser devices to provide optical power and for the lamps to trigger the crystal rod to form a laser. It is used to trigger high currents in short periods of time and apply them to the lamps in the chamber. When the devices are used at high speed and the environment is not sufficiently cooled by air conditioning, electronic components are damaged by overheating. In laser devices with very intensive use, electronic components may be strained and malfunction. In this case, the necessary parts should be replaced with new ones, power tested and restored to working condition.

Water Cooling Systems; The motor, pump, particle filter, deionization filter, quick-connectors, level switches, and temperature sensors used in the water cooling systems for Light Age Epicare devices need to be replaced as necessary. The Epicare Water Cooling System must maintain a constant temperature of approximately 50°C in the Pump Chamber unit to provide the optical power required for the Epicare Laser devices to trigger laser formation in the crystal rod of the lamp. Therefore, the circulating water must be continuously temperature-controlled and distilled. The quality of the distilled water is verified by measuring its microsim and ppm values in the service department. While the distilled water is circulated through the system by a pump, it is filtered through the deionization and particle filters to remove ions and particles. Filters that have reached saturation should be replaced regularly to avoid damage to the water system and pump chamber.

Window Sales; Protective glass sales for Light Age Epicare LPX devices (Window). Epicare Protective Glass; These anti-reflective glasses are placed on the protective glass socket on the top of the handpiece for Epicare laser devices. The laser is applied to the skin through this anti-reflective glass. The cold air blowing tool blows air to the area where the laser touches the skin, preventing the vapor and hair particles from flying around and reaching the lens on the top of the handpiece's fiber end. That's why it's called protective glass. After each operation, it should be checked visually and, if necessary, cleaned or replaced with a new one. Continued use of dirty protective glass may cause heating and damage to the fiber and lens.

Hand Pieces & Accessories Replacement of handpieces, rotating end caps, 9 mm, 12 mm, 15 mm, 18 mm standoffs used in Light Age Epicare LPX, DUO devices. Epicare Handpieces and Cooling Device: Instant cold air application is necessary on the skin where the laser is applied in Epicare laser devices. Therefore, a cooling device should be attached to the handpiece with the same laser region where the cold air will be applied. Our ergonomic functional design provides comfortable use of the cooling apparatus and laser handpiece together.

Skin Cooling Deviceı;We provide maintenance and repair services for skin cooling devices and hoses, including those from Zimmer Cryo 5, Zimmer Cryo 6, and other brands. Our repairs include replacing accessories and ensuring proper functioning. Skin cooling devices such as cryogenic sprays are used to minimize pain and prevent skin damage during laser hair removal treatments. These devices blow air as cold as -40 °C through a hose that is directed at the patient's skin. Due to recurring daily use, the evaporator, condenser, and copper pipes in the device can undergo thermal expansion and contraction. Over time, this can result in gas leaks in the tightly sealed gas system, which requires the replacement of all welded connections and repairs to gas leaks through the correct injection of the appropriate amount of gas. Proper insulation is also necessary for the hoses.

Application Trainings;Light Age Epicare User Training; The treatment effectiveness of laser hair removal devices is very dependent on the users. An effective hair removal treatment can be achieved by applying the correct dose, adjusting the device according to the skin type and hair structure and the appropriate scanning pattern. For this reason, each user can apply the device after receiving practical training from our company. With hands-on laser training, we offer you high quality, comprehensive practical information, the correct settings of the devices and effective treatment parameters.